Load Cells Cable 4 conductor, 6 conductor and Hostile Environment Accessories in the Central Carolina Scale Electronic Catalog

HOSTILE ENVIRONMENT LOAD CELL CABLE
Hostile Environment Load Cell Cable

Standard Features
EL146HE: 4-Wire Load Cell Cable
EL147HE: 6-Wire Load Cell Cable
• Designed for use in hostile environments
• Polyurethane jacketing provides superior chemical and abrasion resistance
• RFI and EMI protected with foil overbraid shield
• Unmatched durability, yet extremely flexible
• All conductors are industry-standard color coded
• Diameter—EL146HE: 0.28" (7.1 mm); EL147HE: 0.32" (8.1 mm)
• The 6-wire cable is best suited for longer runs where remote sense lines can be used
• Use the 4-wire cable for repairing or extending existing cable
• Temperature rating -30°C to 80°C (-22°F to 176°F)

PART # DESCRIPTION - CONTINUOUS FEET (M) EL146HE
15510 .......100 ft ...(30.5) ........4-Conductor Hostile Environment Cable ...................
15511 .......250 ft ...(76.2) ........4-Conductor Hostile Environment Cable .....................
15512 ....... 500 ft ...(152.4) .....4-Conductor Hostile Environment Cable .....................
15513 ....... 1,000 ft (304.8) .....4-Conductor Hostile Environment Cable ..................
15494 .......Custom Length .... 4-Conductor Hostile Environment Cable ......................

PART # DESCRIPTION - CONTINUOUS FEET (M) EL147HE
15520 ....... 100 ft ...(30.5) .......6-Conductor Hostile Environment Cable .....................
15521 ....... 250 ft ...(76.2) .......6-Conductor Hostile Environment Cable .....................
15522 ....... 500 ft ...(152.4) .....6-Conductor Hostile Environment Cable .....................
15523 ....... 1,000 ft (304.8) .....6-Conductor Hostile Environment Cable ..................
15496 .......Custom Length ..... 6-Conductor Hostile Environment Cable ......................

 

 

STANDARD LOAD CELL CABLE

Load Cell Cable


Standard Features
EL146: 4-Wire Load Cell Cable
EL147: 6-Wire Load Cell Cable
• 20 AWG tinned copper wire stranded for flexibility
• Braided shielding is encased in red PVC
• All conductors are industry-standard color coded
• Diameter—EL146: 0.25" (6.4 mm); EL147: 0.29" (7.4 mm)
• The 6-wire cable is best suited for longer runs where remote sense lines can be used
• Use the 4-wire cable for repairing or extending existing cable
• Temperature rating -30°C to 80°C (-22°F to 176°F)

PART # DESCRIPTION - CONTINUOUS FEET (M) EL146
15505 ...... 100 ..... (30.5) .............. 4-Conductor Cable .............................................
15506 ...... 250 ..... (76.2) .............. 4-Conductor Cable ..............................................
15507 ...... 500 ..... (152.4) ............ 4-Conductor Cable ...............................................
15508 ...... 1000 ... (304.8) ............ 4-Conductor Cable ...............................................
15493 ...... Custom Length ............ 4-Conductor Cable ................................................

PART # DESCRIPTION - CONTINUOUS FEET (M) EL147
15515 ...... 100 .... (30.5) ............... 6-Conductor Cable ...............................................
15516 ...... 250 ..... (76.2) .............. 6-Conductor Cable ...............................................
15517 ...... 500 ..... (152.4) ............ 6-Conductor Cable ...............................................
15518 ...... 1000 ... (304.8) ............ 6-Conductor Cable ............................................
15495 ...... Custom Length ............ 6-Conductor Cable ................................................

 

EL147RP Rodent Protection Cable

Standard Features
• Tinned copper overbraid provides superior rodent and abrasion deterent
• Enhanced EMI/RFI protection
• 6-conductor industry-standard color code
• Ideal for truck and railroad track scales
• Diameter: 0.33" (8.38 mm)
• Temperature rating -30°C to 80°C (-22°F to 176°F)

PART # ............ DESCRIPTION
31475 ............. Custom Length Hostile Environment Cable .................
53204 ............. 100 ft (30.5 m) Hostile Environment Cable ....................
53206 ............. 250 ft (76.2 m) Hostile Environment Cable ...................
53207 ............. 500 ft (152.4 m) Hostile Environment Cable ...............
53208 ............. 1,000 ft (304.8 m) Hostile Environment Cable ...........

 

 

EL147IS Hazardous Environment Blue Jacket Cable

Standard Features
• Designed for intrinsically safe applications (must be wired according to Factory Mutual System-approved diagram)
• Polyurethane over PVC double jacketing provides superior chemical and abrasion resistance
• Both foil and braided wire shields for added RFI and EMI protection
• 6 conductors are industry-standard color coded
• Diameter— 0.32" (8.1 mm)
• Suited for longer runs where remote sense lines can be used
• Temperature rating -30°C to 80°C (-22°F to 176°F)

PART # DESCRIPTION
32817 ............. EL147IS ............................................................................................
72241 ............. 3-Conductor ......................................................................................

 

 

Call (919) 776-7737 to order or request a quote by clicking above

Return to loadcells and parts home
 
 

 

EL144 Communications Cable

Standard Features
• 2-conductor with bare ground
• RFI/EMI protected with foil shield
• Perfect for RS-232, 2-wire RS-485, and 20 mA current loop communications
• Diameter: 0.19" (4.8 mm)

PART # .......... DESCRIPTION
32803 ............. EL144 ...............................................................................................
72072 ............. EL144, 500 ft .....................................................................................
72693 ............. EL144, 1,000 ft ..................................................................................

 

 

 

BCD Cable

Standard Features
• Sheathed in gray PVC
• Mylar aluminum foil shield with stranded tinned copper drain wire
• Diameter: 0.375" (9.5 mm)

PART # ...........DESCRIPTION
15497 ............. BCD, 24 AWG, 30-Conductor ............
............................................

 

 

 

SURVIVOR® EL620HE High Temperature Cable

Standard Features
• Multiconductor overall foil and braid shield
• Suitable for high temperatures up to 392°F (200°C)
• Insulation thickness - 0.010" (0.25 mm)
• Jacket thickness - 0.017" (0.43 mm)
• 18 gauge, tinned copper conductors
• Teflon® jacket, resistant to chemical corrosion and high temperature
• Beldfoil aluminum-polyester shield with 85% tinned copper braid shield
• 150V NEC 725 Class 2 classified for use in an airplenum non-conduit

PART # .......... DESCRIPTION
15605 ............. EL620HE ........................................................................................
Teflon is a registered trademark of E.I. Dupont

 

 

Fiber Optic Cable

Standard Features
• Duplex cable polyethylene black jacket material
• 4.4 ± 0.10 mm outer diameter of duplex cable
• 2.2 ± 0.007 mm single cable outer diameter
• Operating temperature: -55° C to 70° C (-67°F to 158°F)

PART # .......... DESCRIPTION
78910 ............. Custom length ................................................................................
78026 ............. 100 ft cable (30.48 m) ......................................................................
78027 ............. 200 ft cable (60.96 m) .......................................................................
78028 ............. 300 ft cable .....................................................................................
83052* ............ Fiber optic connector .........................................................................
80892 ............. Fiber optic cable cutter .......................................................................
85548 ............. Fiber optic hot knife ...........................................................................
* Duplex cable requires two connectors

 

 

EL148HE Replacement Mettler Toledo® Power Cell Cable
toledo power cell cable
The EL148HE replacement Mettler-Toledo™ power cell cable is now made right at the Rice Lake factory in Wisconsin. This extremely durable cable offers 20 gauge stainless steel overbraid construction and features the Mettler-Toledo color code. A textured rubber boot and stainless steel military grade connector are built right in, for the kind of high quality product you’ve come to expect from Rice Lake. The EL148HE comes in standard lengths of 8, 12, 15, 26, and 35 feet. Custom lengths are available upon request.

 

SURVIVOR® Cable Armor

Standard Features
• Flexible all metal protective armor
• Ideal for protecting load cell cable from mechanical abrasion or rodents
• Available in stainless steel and galvanized steel
• 0.5" (12.7 mm) internal diameter, 2.0" (50.8 mm) minimum bend radius
• Optional end fitting with 1/2" male pipe thread

PART # .......... DESCRIPTION
17808 ............. Galvanized steel ............................................................................
17806 ............. Stainless steel ...............................................................................
17807 ............. Optional end fitting ........................................................................
.

 

 

 

Call (919) 776-7737 to order or request a quote by clicking above

 

 

 

Return to loadcells and parts home

 

Bench Scales

Checkweighers

Clinical Scales

Coin Counting Scales

Counting Scales

Custom Applications

Explosion Area Scales

Fishing Scales

Floor & Pallet Scales

Hanging & Crane

Digital Indicators

Laboratory Balances

Lift truck & Pallet jack

Livestock & Farm

Load Cells

Pharmaceutical & Quality Control

Price Computing

Printers

Racing & Wheel Load

Scoreboards

Shipping & Postal

Truck & Heavy Vehicle

Veterinary & Animal

Weights

Contact Info

Home

 

 

 

 

 

History Our Services Location Sales Info Service Info Rentals Info Calibration FAQ Employees Links

© Copyright 2009. All rights reserved. Central Carolina Scale, Inc.