HOSTILE
ENVIRONMENT LOAD CELL CABLE
Standard
Features
EL146HE: 4-Wire Load Cell Cable
EL147HE: 6-Wire Load Cell Cable
Designed for use in hostile environments
Polyurethane jacketing provides superior chemical and
abrasion resistance
RFI and EMI protected with foil overbraid shield
Unmatched durability, yet extremely flexible
All conductors are industry-standard color coded
DiameterEL146HE: 0.28" (7.1 mm); EL147HE:
0.32" (8.1 mm)
The 6-wire cable is best suited for longer runs where
remote sense lines can be used
Use the 4-wire cable for repairing or extending existing
cable
Temperature rating -30°C to 80°C (-22°F to
176°F)
PART
# DESCRIPTION - CONTINUOUS FEET (M) EL146HE
15510 .......100 ft ...(30.5) ........4-Conductor Hostile Environment
Cable ...................
15511 .......250 ft ...(76.2) ........4-Conductor Hostile Environment
Cable .....................
15512 ....... 500 ft ...(152.4) .....4-Conductor Hostile Environment
Cable .....................
15513 ....... 1,000 ft (304.8) .....4-Conductor Hostile Environment
Cable ..................
15494 .......Custom Length .... 4-Conductor Hostile Environment
Cable ......................
PART
# DESCRIPTION - CONTINUOUS FEET (M) EL147HE
15520 .......
100 ft ...(30.5) .......6-Conductor Hostile Environment Cable
.....................
15521 ....... 250 ft ...(76.2) .......6-Conductor Hostile Environment
Cable .....................
15522 ....... 500 ft ...(152.4) .....6-Conductor Hostile Environment
Cable .....................
15523 ....... 1,000 ft (304.8) .....6-Conductor Hostile Environment
Cable ..................
15496 .......Custom Length ..... 6-Conductor Hostile Environment
Cable ......................
|
|
STANDARD
LOAD CELL CABLE

Standard
Features
EL146: 4-Wire Load Cell Cable
EL147: 6-Wire Load Cell Cable
20 AWG tinned copper wire stranded for flexibility
Braided shielding is encased in red PVC
All conductors are industry-standard color coded
DiameterEL146: 0.25" (6.4 mm); EL147: 0.29"
(7.4 mm)
The 6-wire cable is best suited for longer runs where
remote sense lines can be used
Use the 4-wire cable for repairing or extending existing
cable
Temperature rating -30°C to 80°C (-22°F to
176°F)
PART
# DESCRIPTION - CONTINUOUS FEET (M) EL146
15505 ...... 100 ..... (30.5) .............. 4-Conductor Cable
.............................................
15506 ...... 250 ..... (76.2) .............. 4-Conductor Cable
..............................................
15507 ...... 500 ..... (152.4) ............ 4-Conductor Cable
...............................................
15508 ...... 1000 ... (304.8) ............ 4-Conductor Cable
...............................................
15493 ...... Custom Length ............ 4-Conductor Cable ................................................
PART
# DESCRIPTION - CONTINUOUS FEET (M) EL147
15515 ...... 100 .... (30.5) ............... 6-Conductor Cable
...............................................
15516 ...... 250 ..... (76.2) .............. 6-Conductor Cable
...............................................
15517 ...... 500 ..... (152.4) ............ 6-Conductor Cable
...............................................
15518 ...... 1000 ... (304.8) ............ 6-Conductor Cable
............................................
15495 ...... Custom Length ............ 6-Conductor Cable ................................................
|
EL147RP Rodent
Protection Cable
Standard
Features
Tinned copper overbraid provides superior rodent and
abrasion deterent
Enhanced EMI/RFI protection
6-conductor industry-standard color code
Ideal for truck and railroad track scales
Diameter: 0.33" (8.38 mm)
Temperature rating -30°C to 80°C (-22°F
to 176°F)
PART
# ............ DESCRIPTION
31475 ............. Custom Length Hostile Environment Cable
.................
53204 ............. 100 ft (30.5 m) Hostile Environment Cable
....................
53206 ............. 250 ft (76.2 m) Hostile Environment Cable
...................
53207 ............. 500 ft (152.4 m) Hostile Environment Cable
...............
53208 ............. 1,000 ft (304.8 m) Hostile Environment
Cable ...........
|
|
|
|
EL147IS
Hazardous Environment Blue Jacket Cable
Standard
Features
Designed for intrinsically safe applications (must be
wired according to Factory Mutual System-approved diagram)
Polyurethane over PVC double jacketing provides superior
chemical and abrasion resistance
Both foil and braided wire shields for added RFI and
EMI protection
6 conductors are industry-standard color coded
Diameter 0.32" (8.1 mm)
Suited for longer runs where remote sense lines can be
used
Temperature rating -30°C to 80°C (-22°F to
176°F)
PART
# DESCRIPTION
32817 ............. EL147IS ............................................................................................
72241 ............. 3-Conductor ......................................................................................
|

Call (919)
776-7737 to order or request a quote by clicking above
|
|
| Return
to loadcells and parts home |
| |
| |
|
EL144
Communications Cable
Standard
Features
2-conductor with bare ground
RFI/EMI protected with foil shield
Perfect for RS-232, 2-wire RS-485, and 20 mA current
loop communications
Diameter: 0.19" (4.8 mm)
PART
# .......... DESCRIPTION
32803 ............. EL144 ...............................................................................................
72072 ............. EL144, 500 ft .....................................................................................
72693 ............. EL144, 1,000 ft ..................................................................................
|
| |
|
BCD
Cable
Standard
Features
Sheathed in gray PVC
Mylar aluminum foil shield with stranded tinned copper
drain wire
Diameter: 0.375" (9.5 mm)
PART
# ...........DESCRIPTION
15497 ............. BCD, 24 AWG, 30-Conductor ........................................................
|
| |
|
SURVIVOR®
EL620HE High Temperature Cable
Standard
Features
Multiconductor overall foil and braid shield
Suitable for high temperatures up to 392°F (200°C)
Insulation thickness - 0.010" (0.25 mm)
Jacket thickness - 0.017" (0.43 mm)
18 gauge, tinned copper conductors
Teflon® jacket, resistant to chemical corrosion and
high temperature
Beldfoil aluminum-polyester shield with 85% tinned copper
braid shield
150V NEC 725 Class 2 classified for use in an airplenum
non-conduit
PART
# .......... DESCRIPTION
15605 ............. EL620HE ........................................................................................
Teflon is a registered trademark of E.I. Dupont
|
| |
|
Fiber
Optic Cable
Standard
Features
Duplex cable polyethylene black jacket material
4.4 ± 0.10 mm outer diameter of duplex cable
2.2 ± 0.007 mm single cable outer diameter
Operating temperature: -55° C to 70° C (-67°F
to 158°F)
PART
# .......... DESCRIPTION
78910 ............. Custom length ................................................................................
78026 ............. 100 ft cable (30.48 m) ......................................................................
78027 ............. 200 ft cable (60.96 m) .......................................................................
78028 ............. 300 ft cable .....................................................................................
83052* ............ Fiber optic connector .........................................................................
80892 ............. Fiber optic cable cutter .......................................................................
85548 ............. Fiber optic hot knife ...........................................................................
* Duplex cable requires two connectors
|
|
EL148HE
Replacement Mettler Toledo® Power Cell Cable
The
EL148HE replacement Mettler-Toledo power cell cable is
now made right at the Rice Lake factory in Wisconsin. This extremely
durable cable offers 20 gauge stainless steel overbraid construction
and features the Mettler-Toledo color code. A textured rubber
boot and stainless steel military grade connector are built
right in, for the kind of high quality product youve come
to expect from Rice Lake. The EL148HE comes in standard lengths
of 8, 12, 15, 26, and 35 feet. Custom lengths are available
upon request.
|
|
SURVIVOR®
Cable Armor
Standard
Features
Flexible all metal protective armor
Ideal for protecting load cell cable from mechanical
abrasion or rodents
Available in stainless steel and galvanized steel
0.5" (12.7 mm) internal diameter, 2.0" (50.8
mm) minimum bend radius
Optional end fitting with 1/2" male pipe thread
PART # ..........
DESCRIPTION
17808 ............. Galvanized steel ............................................................................
17806 ............. Stainless steel ...............................................................................
17807 ............. Optional end fitting .........................................................................
|